RKI-1 is intended for:
- measurement of insulation resistance and determination of connections with
damaged insulation;
- control of the insulation resistances of each pole relative
to the " ground»;
- monitoring the current in the battery circuit.
- monitoring of the voltage on the operational current buses;
RCT-1 is designed for installation under the following conditions:
- ambient operating temperature range from minus 10°C
to plus 40°C;
- relative humidity - no more than 80% at temperature
25°C;
- altitude above sea level-no more than 2000 m;
- the installation site must be protected from water splashes.,
oils, emulsions;
- the environment is non-explosive, does not contain conductive
dust, aggressive gases and vapors in concentrations that destroy
insulation and metal.
- measurement of insulation resistance and determination of connections with
damaged insulation;
- control of the insulation resistances of each pole relative
to the " ground»;
- monitoring the current in the battery circuit.
- monitoring of the voltage on the operational current buses;
RCT-1 is designed for installation under the following conditions:
- ambient operating temperature range from minus 10°C
to plus 40°C;
- relative humidity - no more than 80% at temperature
25°C;
- altitude above sea level-no more than 2000 m;
- the installation site must be protected from water splashes.,
oils, emulsions;
- the environment is non-explosive, does not contain conductive
dust, aggressive gases and vapors in concentrations that destroy
insulation and metal.
More details
24 828 rub./pcs.
Many
-
+
Documents
3D model
- Description
- Specifications
- Shipping
-
RCT-1 is designed for measuring the insulation resistance and determining connections with damaged insulation, monitoring the insulation resistance of each pole relative to the "ground", monitoring the current in the battery circuit, monitoring the voltage on the operational current buses.
RKI-1 is designed for installation under the following conditions: the operating temperature range of the ambient air from minus 10°C to plus 40°C, the relative humidity of the air-no more than 80% at a temperature of 25°C, the altitude above sea level-no more than 2000 m, the installation site must be protected from splashes of water, oils, emulsions, the environment is non-explosive, does not contain conductive dust, aggressive gases and vapors in concentrations that destroy insulation and metal. -
Basic system parameters:
- Operating range of constant supply voltage, V from 90 to 260;
- Number of controlled operating current sections 1;
- Number of controlled connections up to 100;
- Number of controlled batteries 1;
- Measuring range of insulation resistance, kOhm from 1 to 2 000;
- The relative error in determining the insulation resistance of the network poles is not more than 10%;
- The relative error in determining the insulation resistance of the connections is not more than 15%;
- The measurement error of the insulation resistances of the connection poles, when the voltage on the operating current buses is less than 0.5, the nominal value is not normalized;
- Cycle time for measuring the resistances of all connections, s, no more than 60;
- Maximum capacity of the monitored network, UF, no more than 50;
The system measures the voltage on the operating current buses:
- the maximum permissible value of the measured voltage up to 1.25 of the nominal value;
- the relative error of voltage measurement, not more than 1%.
-
Delivery in Cheboksary is free of charge.
If you order delivery in Cheboksary before 13 hours, delivery is carried out the next day.
The courier is closed on weekends and public holidays.
Delivery in Russia and the CIS countries (Belarus, Kazakhstan, etc.) is carried out through the transport company of your choice. The delivery time depends on the selected company and your location. The exact cost of delivery is calculated by your manager after placing an order on the website or sending an email request. The delivery terms are calculated based on the tariffs of the transport service you selected.
Delivery to the terminal of the transport company in Cheboksary - free of charge!
We work with the following transport companies:
SDEC;
Business lines;
PECK;
Russian Post;
you can also call a courier or pick up the goods by pickup.
Ask a question